EBST
Model | Voltage [V] | Max Current [A] | Speed [rpm] | Max Power [W] | Max Airflow [m3/h] | Noise [dB(A)] | |
| A180P.D002 | 48 | 4.70 | 5900 | 227 | 1335 | 78 |
Powered by 48V DC, the fan perfectly matches standard data center power architectures, eliminating high-voltage risks and simplifying integration with row-based cooling systems.
Delivering up to 1335 m³/h airflow at 5900 rpm, it meets the high-density cooling requirements of modern IT racks, ensuring rapid heat removal and stable cold aisle temperatures.
Optimized design achieves powerful airflow at only 227W rated power, reducing energy consumption of the cooling system and directly supporting your data center’s low-PUE goals.
The standard 180mm size fits seamlessly into the limited space of row-based precision air conditioners, enabling easy installation and drop-in replacement without extra modifications.
Designed with industrial-grade DC motors and long-life bearings, the fan delivers stable, maintenance-free operation in continuous-duty data center environments, minimizing downtime and operational costs.
Q1: Why do these fans use 48V DC power instead of AC?
A1: 48V DC is the industry standard for data center safety. It eliminates high-voltage shock risks, aligns with common DC power distribution in data centers, and enables seamless integration with backup power systems, ensuring stable cooling even during power transitions.
Q2: Can this 180mm axial fan handle high-density cooling demands of modern IT racks?
A2: Absolutely. With a maximum airflow of 1335 m³/h at 5900 rpm, it delivers powerful airflow tailored to the tight space of row-based AC units. It efficiently removes heat from high-density racks, maintaining stable cold aisle temperatures and preventing hotspots.
Q3: How do these fans help reduce the data center’s PUE?
A3: The optimized design achieves high airflow with low power consumption (only 227W rated power). Combined with intelligent speed control (e.g., PWM/0-10V), it adjusts airflow based on real-time cooling needs, cutting unnecessary energy use and directly supporting low-PUE goals.
Q4: Is the 180mm form factor compatible with most existing row-based precision air conditioners?
A4: Yes, the standard 180mm size is designed for drop-in replacement. It fits seamlessly into the typical installation space of row-based AC units, requiring no major modifications. Pre-drilled flange holes also simplify on-site installation.
Q5: How long is the service life, and what maintenance is required?
A5: Built with industrial-grade DC motors and long-life bearings, these fans are rated for over 60,000 hours of continuous, maintenance-free operation. They are engineered for 24/7 data center environments, minimizing downtime and reducing long-term operational costs.